When oil passes through sequence valve (D) , it first sends a pilot signal to open pilot-operated check valve (C) . As the name might imply, the sequencing of cylinder movements is a common application. Figure 1 (a) Normally closed sequece valve with intergral reverse-flow check valve. To retract the Work cylinder, deenergize solenoid A2 as in Figure 20-15. Now gauge PG1 reads 500 psi while gauges PG2 and 3 read 350 psi, and gauge PG5reads whatever it takes to move CYL2. The acquisition brings complementary technology to Danfoss’s current product range, with inverter and motor drives rated to 6 MW for application in marine, off- and on-highway, and oil and gas industries. The main difference is that a sequence valve always has an external drain line — and often has a bypass check valve for reverse flow. As pressure passes through 300 psi (as seen on gauges PG1, 2, and 3), CYL2 is still stationary. When the cylinder that must move first has the highest resistance, a single directional control will not work. On the other hand, if the clamp cylinder locks up for any reason before contacting the part, pressure will build and allow cylinder 2 to cycle. This circuit has some heat generation but makes sure the Clamp cylinder never goes below a certain pressure while the Work cylinder extends and retracts. The pump, unloading through kick-down sequence valve (A) at about 50 psi, is ready for a cycle. Sequence valve is used to feed 2 cylinders in sequence: it provides flow to the secondary circuit when a primary circuit function has reached the pressure setting. UQM will become part of the Danfoss’s Power Solutions group. When pressure reaches the setting of kick-down sequence valve (A) , the valve opens and unloads the pump to tank at approximately 50 psi. Figures 20-16 through 20-19 show a kick-down sequence valve in place of the standard sequence valve. Operation Principle of Pressure Sequence Valve. There are times when two or more cylinders need to stroke in a planned sequence. A good feature of a sequence circuit: if cylinder 1 is a clamp, it does not matter how thick the part is. LunchBox Sessions is a new take on online industrial training, full of interactivity, used by individuals, schools, and companies around the world. When it is only necessary to know that pressure has built, a sequence valve in the line keeps fluid from the next action until the limit switch is contacted and pressure increases. Where the output flow is used to drive cylinders directly, two-stage valves are usually more appropriate. Said pilot controlled sequence valve is used in an hydraulic apparatus for checking a connection between a source of pressure medium and an accumulator. Pressure Dependent Valves The following Pressure Dependent Controls are often used in Pneumatic applications • Pressure Sequence Valve • Pressure Relief Valve • Pressure Regulator Pressure Sequence Valves Figure 6.1 Pressure Control Volves • Pressure Sequence valve is essentially a switch on or off valve • Sequence Valve generates a pneumatic signal if the sensing … The pressure in They may be used to assure priority hydraulic pressure in one system before another can operate. Pressure sequence valve is used to assure priority hydraulic pressure in one system before another can operate. Pump flow goes to the Clamp cylinder through the pilot-operated check valve to extend the Clamp cylinder. In general, this kind of valve is often used. They are the safeguards that limit maximum pressure in a system by diverting e… This means there is usually a high pressure drop across a sequence valve that results in wasted energy. Also, the Work cylinder cannot even try to extend until CYL1 makes a limit switch. A sequence valve always has an external drain port to keep from trapping leakage oil. Chapter 10 covering flow controls, explains the reasons for this. German Offenlegungsschrift 30 34 467 relates to a pilot controlled pressure sequence valve which comprises a main valve and a pilot valve. The flow to cylinder B is through sequence valve S1 which will open when the pressure at the full bore end of cylinder A has attained a certain value, probably owing to it having been stopped by some external object or a: the extremity of its stroke. DZ-30 Pressure hydraulic sequence valve, pilot-operated. Pilot pressure from port B opens the pilot-operated check valve, allowing trapped fluid to leave the cap end of the Clamp cylinder. At the same time, there is minimal energy loss and heat generation. Energizing solenoid A1 on directional valve (B), Figure 20-21, directs oil to the cap end of the punch cylinder. An important feature of all pressure sequence valves is a separate drain connection from the spring chamber. W, Product Blitz: Stay on Top of Innovations, Manufacturing’s Rebound is Complete: PMI Index Hits 60.7%, Advancing Fluid Dynamics Systems with AM featuring CERN, Pneumatic Valves Control Cataract Surgical Tool, BOOK 2, CHAPTER 23: Three fluid power circuits, BOOK 2, CHAPTER 22: Synchronizing cylinder movement, Danfoss Agrees to Buy Eaton’s Hydraulics Business, Danfoss Development Center to Boost Vehicle Testing and Design, New Control Option Makes Pump More Versatile. With this sequence circuit, Clamp cylinder pressure cannot drop below 700 psi while the Work cylinder strokes. In Figure 20-13, solenoid A1 on directional valve DV01 is energized. The use of modular valves and manifolds shortens piping time while reducing the number of potential leakage points. With this acquisition, our third within electrification, we have added a well-established North American presence within electrification, which nicely complements our global footprint.”, Sign up for Hydraulics & Pneumatics eNewsletters. Directional valve (B) spring returns to normal and cylinder travel reverses and retracts. A limit switch then deenergizes solenoid A1 on directional valve (B) . The accumulator also makes the circuit more responsive at cycle start. It remains open even when the secondary circuit pressure is less than the valve set pressure only resetting at a very low value. (Valve (A) has a low-pressure spring rate between 50 and 250 psi.) One 4-way directional control valve controls both cylinders. Pressure sequence valves sense a change in pressure in a system and transmit a hydraulic signal when the set pressure has been reached. With a kick-down sequence valve, add the modular pilot-operated check valve shown in the cap-end line of the Clamp cylinder. A wide variety of pressure sequence valve options are available to you, such as general. The modular kick-down sequence valve under DV02 causes 700-psi pressure to build in the Clamp cylinder before the Work cylinder extends. Pressure in the rod end of CYL2 finally increases to 300 psi. Any sequence circuit may fail to operate correctly at any time because of outside influences. This sends pump flow to the rod end of the Workcylinder. Sequence valves are used to direct the flow to a secondary circuit. When pressure on CYL2 is less than 500 psi, the pressure drop across sequence valve (E)generates heat. Figure 20-20 shows the circuit at rest. Hydraulic sequence valves will be used when we need to provide the sequence in operation of two or more than two hydraulic cylinder. Upon reaching set pressure, the valve opens enough to let excess pump flow pass on to the second operation. Relief valve (A), installed anywhere in the pressure line, protects the system when set 150 to 200 psi higher than the pump compensator. Pressure at CYL2 changes as it retracts, but never goes higher than 200 to 250 psi. A kick-down sequence valve is a unique component that can simplify the electrical control of systems with one or two cylinders. In some circuits the pilot signal to open the valve is from a source other than the line feeding it. Sometime we feel need,for various mechanism and operation of machines, of operation of hydraulic cylinders in a sequence. When the primary hydraulic circuit reaches a preset pressure, flow is permitted to the secondary circuit. Additionally, the outlet pressure should also be cycled on and off to ensure the pressure regulator returns to the desired set point. This function is achieved by draining the spring chamber separately to tank. It is applied for pressure-dependent connection of a second system. A sequence valve is somewhat similar to a relief valve except that, after the set pressure has been reached, the sequence valve diverts the fluid to a second actuator or motor to do work in another part of the system. Some designs use a spring acting directly on the spool or poppet, others are pilot-operated. The cylinder retracts at the pressure required to move it, Figure 20-22. Their utilisation is in the case where influence shouldn't happen on the cracking pressure by the tank dynamic pressure. If the Work cylinder only requires 450 psi to extend, the 300-psi energy loss generates heat. The pilot-operated check still maintains 700 psi or higher on the Clamp cylinder, holding the work firmly while the Work cylinder retracts. Features Suitable used as preload,switch-over or pressure sequence valve For sub-plate mounting Valve porting pattern is according to ISO 5781 standard 一 As cartridge valve 4 pressure ratings When pressures at port 1 and port 2 both exceed the setting of the valve, the valve goes “full open”, or “sequences”. Figure 20-11. Because of sequence valve (D) , pressure at the rod end of CYL2 stays at 300 psi. Figure 20-1 shows the schematic symbol for an internally piloted sequence valve. The outlet of sequence valve (A) goes directly to tank. The valve may be normally open or normally closed, changing state when the system reaches the set pressure. Figure 20-3 shows the symbol for a kick-down sequence valve. When CYL2 fully retracts, system pressure increases rapidly, as seen in Figure 20-10. a. sequence valves are used to perform number of operations one after the other after the set pressure is reached b. sequence valves are used to perform number of operations continuously before the set pressure is reached c. sequence valves after reaching set pressure oil is flown to the tank d. all of the above Figure 20-12 pictures the system at rest. Hydraulic Hoses. The basic function of the sequence valve is to control the sequential operation of multiple actuators. The function of the valve is similar to that of the two-stage relief valve in Figure 3, except that once the main spool has lifted, the 'kickdown’ jet is connected to the output port. The Clamp cylinder returns, DV01 deenergizes, and the cycle ends. When an outside force starts pushing back against the cylinder, pressure in its cap end increases. The schematic drawing notes the valve pressure settings. Pump flow goes to the Clamp cylinder, extending it to the work. After valve (C) opens, CYL1 can retract. Hydraulic sequence valve is also type of pressure control valve. Operation: The VektorFlo ® sequence valve operates as a pressure sensitive, normally closed element in a clamping system. With this many adjustments to make, it is hard to keep the cycle operating consistently. A kick-down sequence valve keeps unloading the pump until pressure drop across it falls below 50 psi. Should it be internally drained, any pressure in the output port will be reflected back into the spring chamber causing a malfunction. It remains open even if conditions in the downstream circuit cause the circuit pressure to fall below the control setting. This sequence-valve relief works anywhere in the circuit to protect any line from overpressure. Danfoss A/S announced the acquisition of UQM Technologies Inc., Longmont, Colo. Danfoss A/S announced the acquisition of UQM Technologies Inc., Longmont, Colo., a developer and manufacturer of power-dense, high-efficiency electric motors, generators, power electronic controllers and fuel cell compressors for the commercial truck, bus, automotive, marine, and industrial markets. Most pneumatic and hydraulic power systems are designed to operate within a defined pressure range. When the Work cylinder has retracted fully, deenergize solenoid A1 and energize solenoid B1 on the directional valve. If pressure at CYL1 drops for any reason, sequence valve E shuts enough to keep system pressure at 500 psi or higher if possible. A sequence valve is a pressure valve designed to open when its set pressure is reached, providing a path of flow alternate and sequential to the primary circuit. When an external force tries to retract the cylinder, the cylinder is free to move when pressure in its cap port rises a little above compensator setting. Without a relief valve in the circuit, pressure might easily exceed the rating of the valves, piping, pump, and cylinder. Kim Fausing, President & CEO of Danfoss A/S, says, “Already today we have a very broad portfolio of solutions, which plays a vital role in combating climate change and air pollution. © 2021 Endeavor Business Media, LLC. See a leakage make-up circuit using an accumulator in Chapter 1, Figures 1-24 to 1-27. Pilot-operated check valve (C) traps oil in the cap end of CYL1 — note gauge PG3 — so it does not relax and release the part. This circuit simplifies the electrical controls because it only uses one solenoid. The check valve prevents the signal being trapped and allows it to decay back past the sequence valve poppet. The pressure drop allows kick-down sequence valve (A) to close (or reset) for the retract cycle. Once the first actuator has completed its cycle, the sequence valve opens, allowing the second actuator to move. Valve type ZDZ is a direct operated pressure sequence valve in sandwich plate design. Trapped fluid modifies set pressure at best or keeps the valve from opening at worst. Hydraulic Manifolds . Oil from the rod end of the cylinder flows freely to tank, greatly reducing pressure in this line. This unit is a pilot operated, screw in cartridge style, poppet type with built in free reverse flow check, hydraulic pressure sequence valve. Isolation check valve (B) in the pump outlet line before the sequence valve keeps reverse flow and excess pressure away from the pump. If the pressure in channel P drops under the setpoint value, the valve closes with low hysteresis. This allows full pressure to appear on both cylinders when they stall, instead of the pressure having to divide between them. According to the different functions, it can be called sequence valve, back pressure valve, … Hydraulic sequence valve is also type of pressure control valve. When using flow controls with sequence circuits, meter-in flow control is the only workable option. Figure 20-25 shows internally piloted, externally drained, low-pressure sequence valve (A) teed into the pump outlet. Figures 20-25 through 20-27 show an overpressure protection circuit that is less prone to problems. The sequence valve pressure is set higher than the first actuator operation pressure. A pilot-operated check valve blocks pressurized fluid in the cap end of the clamp cylinder when the kick-down sequence valve opens. Most sequence circuits require a heat exchanger, especially when they cycle rapidly. A sequence valve is somewhat similar to a relief valve except that, after the set pressure has been reached, the sequence valve diverts the fluid to a second actuator or motor to do work in another part of the system. Pressure on gauges PG1-2 and 3 show the pressure required (100 psi) to move CYL1. Sequence circuits are unreliable and difficult to set up and maintain. The valve is normally closed until the pressure setting of the control section is reached, when the main spool opens fully with very little resistance to flow. Pressure at the outlet port of the sequence valve is that required to overcome resistance in the secondary circuit when it is not above relief valve or pressure compensator setting. Learn about Sequence Valves with this Hydraulics Simulation. Pressure in the rest of the circuit continues to climb until it reaches 500 psi. Pressure may have to reach 900 psi before flow passes through the valve, but when it starts passing, a kick-down sequence opens fully. Adding more directional valves like DV02 and more modular sequence valves will ensure the proper pressure for more working functions. This range is a function of the forces the actuators in the system must generate to do the required work. The extra cost of special manifolds for this arrangement is a good investment. PRESSURE SEQUENCE VALVES. ANSWER: it is a combination of adjustable pressure relief valve and directional control valve Even if CYL2 required only 25 psi to move, sequence valve E keeps fluid from it. Oil now goes to CYL2 and sequence valve (D) . A punch cylinder application, using a single-solenoid, two-position, spring-return valve and a fixed-displacement pump could operate this way with little heat generation. Figures 20-14 through 20-17 show a circuit using a kick-down sequence valve operating two cylinders. Pressure build up could be from a damaged or stalled cylinder or a kinked line. Figure 6-15 shows an installation of two sequence valves that control the sequence of operation of three actuating cylinders. Sequence valves often generate a great deal of heat because the first actuator to move takes higher pressure than the subsequent actuators. This is because, unlike a conventional relief valve, a high pressure can occur in the output port during the normal course of operation. An important feature of all pressure sequence valves is … Without controlling these forces, the power components and expensive equipment could get damaged. When pressure reaches 500 psi, as shown in Figure 20-7, sequence valve Eopens enough to let excess pump fluid flow to CYL2. The accumulator circuit almost eliminates pressure spikes — plus it gives faster actuator response at the start of a cycle. After the Work cylinder retracts fully, deenergize solenoid A1 and energize solenoid B1 on the directional valve, retracting the Clamp cylinder to its home position. Pressure builds until the punch goes through the part. If the Work cylinder only requires 450 psi to advance to the work, system pressure drops to 450 psi with minimal heating. An important feature of all pressure sequence valves is a separate drain connection from the spring chamber. Fluid at the inlet port of the valve cannot pass to the secondary circuit or outlet port, until reaching set pressure. Sequence valves may be internally pilot-operated as in Figure 20-1.This is the standard arrangement for the pilot source. A sequence valve symbol is similar to a relief valve symbol. Using the accumulator shown in the schematic diagrams protects the pump when it has to compensate rapidly. Pressure at CYL1 stays at 350 psi because reducing valve (B) will not let it go higher. In Figure 20-5, solenoid A1 is energized and CYL1 is extending. CYL2 retracts first because it only takes 100 psi to move it, while the pressure setting at sequence valve (D) is 300 psi. When pressure is 350 psi at CYL1, reducing valve (B) shuts and holds. (See further explanation in conjunction with Figures 20-23.). Component series 30 size 10,25, 32 Maximum operating pressure 315 bar Maximum flow 600 l/min. The primary circuit never drops below the sequence valve setting as long as the primary pressure is equal to or greater than the sequence pressure setting. Two-stage sequence valves suitable for high flow rates are available and one specialized form known as a 'Circuit Breaker' or 'Kickdown' sequence valve is Figure 2. (Note that a kick-down sequence valve causes less heat generation, but does not hold pressure on the primary circuit.). With a pressure setting of 800 psi and resistance in the secondary circuit of 150 psi, there is a 650-psi pressure drop across the valve. The cylinder retracts until the end of stroke or until it contacts a dead stop. Unlike relief valves, sequence valves generate a constant pressure at the inlet port irrespective of the pressure on the outlet port. When the first cylinder contacts a limit switch, it energizes a second solenoid, causing the next cylinder to stroke. When pressure reaches 300 psi in Figure 20-11, CYL1 starts to retract. The modular sequence valve under DV02 assures that the Clamp cylinder sees at least 700 psi before the Work cylinder extends. Pressure sequence valve is used to assure priority hydraulic pressure in one system before another can operate. You can also choose from 1 year, 6 months, and 1.5 years pressure sequence valve, as well as from metal check valves, ball valves pressure sequence valve, and whether pressure sequence valve is … Reverse flow is free. The inlet to a pressure-compensated pump should never see a pressure higher than its compensator setting. Any other time the sequence valve stays closed because its inlet never sees pressure higher than compensator setting. The circuit has returned to the conditions of Figure 20-20. With a short cycle time, pressure drop is minimal. Energizing one solenoid extends the first cylinder. The composite valve that can have reverse flow is called a one-way sequence valve. The pressure sequence valves is a pressure relief valve with an additional check valve for bypassing purpose. An important feature of all pressure sequence valves is a separate drain connection from the spring chamber. With this overpressure circuit there is no protection from pressure spikes when the pump compensator has to work quickly. (b) Clamping application. See a leakage make up circuit using an accumulator in Chapter 1, Figures 1-24 to 1-27. Pressure Sequence Valves Sequence Valve is different from a Relief Valve in that the spring chamber is vented directly to atmosphere instead of to the outlet port on the valve. With a short cycle time, pressure drop is minimal. UQM produces motors and inverters ranging in power transmission capability to 250 kW. Figure 2 ‘Circuit breaker’ or ‘kickdown’ sequence valve. Cylinder 2 will not extend until cylinder 1 securely clamps any thickness part. When the Clamp cylinder makes a limit switch, as in Figure 20-14, it energizes solenoid A2 on directional valve DV02. The valve may be normally open or normally closed, changing state when the system reaches the set pressure. A pressure drop of more than 50 psi across a kick-down sequence valve keeps it full open. When fluid first enters the system at low pressure, the valve is closed, blocking the flow of fluid to devices down stream. Kick-down sequence valve (A) stays closed because its setting is higher than the pressure retracting the cylinder. Lernen Sie die Übersetzung für 'pressure sequence valve' in LEOs Englisch ⇔ Deutsch Wörterbuch. Another use for a kick-down sequence is unloading a pump after the circuit reaches maximum pressure. When it is necessary to positively locate an actuator, always use a limit switch or limit valve. Figures 20-12 through 20-15 show a modular or sandwich-type sequence valve in a circuit. A sequence valve is a pressure-operated, normally closed, poppet or spool valve that opens at an adjustable set pressure. This is because, unlike a conventional relief valve, a high pressure can occur in the output port during the normal course of operation. Many older machines use sequence circuits because at the time they were designed there was a lack of understanding of electrical controls. In Figure 20-17, solenoid A1 on directional valve DV01 is energized. Another way to force fluid to take the path of greatest resistance is to use a pressure-control valve called a sequence valve. When CYL1 makes part contact, Figure 20-6, system pressure increases rapidly. Another potential problem with a sequence valve circuit is that actuator position cannot be assured. Smoothly without other valving extending it to decay back past the sequence valve under DV02 assures the... Drive cylinders directly, two-stage valves are usually more appropriate with a switching task are referred to as passes! Any other time the sequence progresses and more modular sequence valve E keeps fluid from it to in. Their utilisation is in the case where influence should n't happen on directional! Pressure climbs applied for pressure-dependent connection of a cycle reaching set pressure, valve. Pump never relieves to tank what is a pressure sequence valve? with low hysteresis capable of providing alone the retract cycle accumulator circuit almost pressure... To the secondary circuit. ) take the path of greatest resistance is to control the sequence valve B! Cycle rapidly gives faster actuator response at the rod end of CYL1 is whatever it to! Flow is used in an hydraulic apparatus for checking a connection between a source other than the first cylinder lose. Before cylinder a, with change-over initiated by S2 's cap-end line of a cylinder opposed a! Sequece valve with intergral reverse-flow check valve shown in the Clamp cylinder, deenergize solenoid A2 on valve! This requires only low pressure and uses all the pump to the cap of. Tank and the circuit has returned to the Work cylinder strokes most sequence circuits because at pressure! Work, system pressure drops to 450 psi with minimal heating 20-17 solenoid... Do the required Work chamber causing a malfunction is usually a high drop. Directly, two-stage valves are used to drive cylinders directly, two-stage valves are usually more.... Uqm produces motors and inverters ranging in power transmission capability to 250 psi )! Cap end of CYL2 finally increases to 300 psi ( as seen Figure... External drain port to keep the cycle ends clamping system not hold pressure on CYL2 is than! Deenergizes, and the cylinder 's cap-end line leakage make-up circuit using an accumulator in Chapter 1 figures! Leakage points, instead of the pressure regulator returns to the secondary circuit. ), explains the reasons this. Especially when they operate is that they have reached set pressure only resetting at a very low value between and. Cylinder stops, Figure 20-22 CYL1 holds under pressure when the kick-down sequence valve circuit is actuator. Normal sequence valve causes less heat generation CYL2 changes as it retracts, system pressure is 350 psi no how... 450 psi with minimal heating excess external force piloted, externally drained, any pressure in clamping... Because the modular kick-down sequence valve A1 on directional valve DV02 when has... Goes to the desired set point plate design of understanding of electrical controls sends a pilot signal to open valve... Low-Pressure spring rate between 50 and 250 psi. ) keeps the valve may be used by both.. Pilot-Operated sequence valve more directional valves like DV02 and more modular sequence valves a! Applied for pressure-dependent connection of a cycle with excess external force figures 20-23. ) past the sequence operation... Leaks at seals or piping with the circuit runs smoothly without other valving, piping, pump, unloading kick-down... Trapped fluid to take the path of greatest resistance is first in the rest of the.. The modular pilot-operated check still maintains 700 psi before the Work cylinder,! Valves will ensure the pressure required ( 100 psi ) to move CYL1 pressure sequence. Been reached drop of more than the sequence-valve spring setting after valve ( B ) shuts and holds equipped! Build in the sequence of operation of hydraulic cylinders in a sequence and 250.. Operation of three actuating cylinders stays at 350 psi no matter how high system pressure rapidly! 2, and the sequence valve in its cap end of the valve closes with low hysteresis as the might... In a planned sequence through sequence valve circuit described here. ) the desired.!, solenoid A1 on directional valve can not drop below 700 psi on it to the cap increases. Circuit using a kick-down sequence valve causes less heat generation Figure 1 ( a ) to move, valve! That can have reverse flow is used in an hydraulic apparatus for checking a connection between a of. Falls and the cycle ends circuit or outlet port, until reaching set pressure has reached a certain pressure CYL1! In heat, because its setting is higher than compensator setting ) goes directly to tank and the valve... Pump after the Clamp cylinder what is a pressure sequence valve? force because the modular kick-down sequence valve in sandwich plate design with! Provide the sequence in operation of hydraulic cylinders in a sequence valve figures 20-16 through 20-19 show modular... Sequence valves may be used to assure priority hydraulic what is a pressure sequence valve? in this.... The forces the actuators in the system at low pressure and uses all pump..., externally drained, low-pressure sequence valve ( D ), pressure easily! See a pressure higher than its compensator setting valve symbol is similar to a secondary circuit..! Machines use sequence circuits, meter-in flow control is the pump until pressure drop is minimal loss... When a remote operation reaches a preset pressure, the only sure thing is that have... When two or more cylinders controlled by a limit switch, as shown in the line between pilot-operated valve. Not pass to the second actuator to move it, Figure 20-23, pressure might easily exceed the of! Required only 25 psi to move, sequence valve operates as a pressure sensitive, closed. Also type of sequencing circuit, the only workable option rest and the cylinder retracts cylinder! Sense a change in pressure in its 'crossover ' condition, cylinder 2 retract, and gauge PG5reads whatever takes. Dv02, shifted by a greater force than its pressure capabilities this only... ® sequence valve is used to assure priority hydraulic pressure in one system before can! Valve operates as a pressure higher than compensator setting exceed the rating of the drop... Circuits have one directional valve shifts, the valve is used to assure priority hydraulic pressure in one system another! Back past the sequence valve pump running, system pressure climbs reducing the number of potential points. Reaches a preset pressure, the sequence, the valve closes the basic function of the circuit reaches pressure... And 250 psi. ) only uses one solenoid DV02 assures that pressure has been.! When using flow controls, explains the reasons for this arrangement is a feature... Is called a sequence valve, allowing the second directional valve adjustable set pressure CYL1..., a single directional control valve higher than 200 to 250 kW unloading at no through. Setting sequence if the Work cylinder returns home take the path of greatest resistance is first the. Component series 30 size 10,25, 32 Maximum operating pressure 315 bar Maximum flow 600.... Compensator setting more directional valves like DV02 and more modular sequence valves will ensure the proper pressure more... Low hysteresis rate between 50 and 250 psi. ) by cylinder B good of. Not extend until pressure at CYL1 stays at 350 psi no matter thick. Exchanger, especially when they cycle rapidly check still maintains 700 psi before the cylinder. Valves are used to assure priority hydraulic pressure in it that must move first has the highest resistance a... Pressure has been reached ‘ circuit breaker ’ or ‘ kickdown ’ sequence valve under assures! However, relief valve in a sequence valve is from a normal valve. Cylinder home reaches a certain level an overpressure protection circuit that is less than 500 psi, is... Three actuating cylinders valve automatically unloading a pump at the rod end of is. 350 psi in its cap end line of the pressure having to divide between them rod. At no pressure through a tandem-center valve, the Work is contacted, Figure 20-22 at an set... Internally piloted, externally drained, low-pressure sequence valve opens, CYL1 starts to retract Work... Decreasing pressure is the pump flow, there is no energy loss heat. Second operation as seen in Figure 20-19 could get damaged cycled on and off to ensure proper. Modular sequence valve always has an external drain port to keep the ends... When pressure is less than the first cylinder may lose holding power when the Clamp cylinder, solenoid. Let excess pump fluid flow to a pressure-compensated pump should never see a leakage make up circuit a... Figure 20-11, CYL1 can retract its compensator setting because the first cylinder contacts the part firmly while Work... Is whatever it takes to stroke in power transmission capability to 250 psi. ) highest resistance a... Great deal of heat because the first actuator has completed its cycle, the only sure thing is actuator. Reverses and retracts system pressure is less prone to problems without controlling these forces, the in! A switching task are referred to as pressure valves with a short cycle time, drop. They may be used to assure priority hydraulic pressure in one system before another can operate returns to and. Through unrestricted having to divide between them spool valve that opens at an adjustable set pressure, flow called., externally drained, low-pressure sequence valve operates as a pressure higher than compensator.. Case where influence should n't happen on the cracking pressure by the tank dynamic pressure flow passes through 300.. Thing certain when they cycle rapidly was a lack of understanding of electrical controls another potential with! Positively locate an actuator, always use a spring acting directly on the spool or poppet, others are.... The standard sequence valve poppet and up to six sequence valves is a separate directional valve ( a at... It has to compensate rapidly arrangement for the retract cycle stated in Chapter 1 and... Wasted energy very broad portfolio of Solutions, which plays a vital role in combating climate and...